電(diàn)池ETM-IS11-113
Section 1: System Specification3 X LC / ss / ET / OV / PC / PASize3 = MiniPurge®Purge flow rate:1500 NI/minApproval / CertificationSira 01ATEX1295X 0518 II 2(2) GDEx [pxb] ia IIC T5 GbEx [pxb] ia IIIC T100ºC DbTamb -20ºC to +55ºCIECEx SIR07.0027XEx [pxb] ia IIC T5 GbEx [pxb] ia IIIC T100ºC DbTamb -20ºC to +55ºCTÜV 12.1462XEx [pxb] ia IIC T6 GbEx [pxb] ia IIIC T95ºC DbTamb -20ºC to +55ºCPC = Pressurized Control. Automaticleakage compensation (CLAPS)OV = Purge Outlet Valve ispneumatically operatedTiming MethodET = Electronic TimerMiniPurge® Housingss = Stainless Steel 316LPressurization MethodLC = Leakage Compensation
MiniPurge® Control Unit DataAction on Pressure Failure: Alarm and Trip (isolate power to pressurized enclosure), useradjustable Alarm Only.Type of Operation: Automatic leakage compensation using the Closed Loop AutomaticPressurization System (CLAPS System).Leakage Compensation Capacity: 500 NI/min initial maximum pressurized enclosure leakage.Enclosure Material: Stainless Steel 316L.Mounting Method: Wall mounting straps. Fixing holes as per drawing.Temperature Limits: -20oC to +55oCCompressed Air Supply: Clean, dry, oil free air or inert gas. Refer to Air Supply Quality sectionin Installation of the System.Supply Pressure: 4 to 8 barg (60 to 115 psi).Main Regulator: Set at 4 barg, 40 μm automatic drain supply inlet filter.Logic Regulator and Gauge: Fitted and set to 2.3 barg (33 psi).Process Connections: Purge supply and outlet to pressurized enclosure 1/2” NPT female.Minimum supply line 13 mm (1/2”) ID tube, inlet sized appropriately forflow rate.Reference points & signals 1/8” NPT female, minimum 6 mm pipe tobe used.Visual Indicators: Alarm (Red ) / Pressurized (Green ).System Purging: 4 LEDs that flash sequentially to indicate elapsedtime (black when not purging)./PA Terminal Box: Glass reinforced polyester box with terminals and accessible cableglands. Certified to 2 Watts power dissipation: Ex e IIC T6 Gb / Ex tbIIIC T85ºC Db IP67 Tamb : -65ºC to +55ºC.Power Interlock Switch: DPNO switch, contact ratings 250 Vac 4 Amps (AC-15) / 24V DC 4A,Ex d IIC T6 Gb / Ex tb IIIC T80ºC Db.Alarm Switch: SPCO switch, contact ratings 250 Vac 4 Amps (AC-15) / 24V DC 4A,Ex d IIC T6 Gb / Ex tb IIIC T80ºC Db.Minimum Pressure Sensor: Minimum: 0.5 mbarg.Maximum: 5.0 mbarg.Default Setting: 1.5 mbarg.Tolerance -0, +0.7 mbarg.Purge Flow Sensor: Set at 6.4 mbarg (Tolerance: -0, +10%).CLAPS Sensor: Minimum: 5.0 mbarg.Maximum:15 mbarg.Default Setting: 10 mbarg.Tolerance: -0, +10%Note: there must be a 2.5 mbarg difference between the intermediate and CLAPS sensor calibration point.For example: Minimum pressure = 5 mbarg, intermediate pressure = 6.5 mbarg, CLAPS sensor = 9 mbarg.Purge Time: User selectable, in 1 minute intervals, up to 99 minutes (tolerance -0, +3 seconds).Default Setting 99 minutes.Weight: 16 kg (35lb).